EF-PowerOcean-TcpModbus

hacs_badge GitHub release

Local Modbus TCP integration for the EcoFlow PowerOcean Plus home battery system.

⚠️ This integration communicates directly with your device over your local network via Modbus TCP. No cloud connection required.


Features

  • Local polling – no EcoFlow cloud account needed
  • Configurable poll interval (5–60 seconds, default 10 s)
  • Real-time power flow: house consumption, grid import/export, solar generation, battery
  • Full battery monitoring: SOC, voltage, current, power, temperature, remaining energy
  • Per-string PV power and current (configurable 1–3 strings, phantom current filtering)
  • Per-phase AC measurements: voltage, current, frequency, apparent power
  • Energy counters: daily and lifetime for grid, solar, battery charge/discharge, house consumption
  • Configurable battery capacity (workaround for unreliable register value)
  • Reconfigurable after setup via Settings → Configure (no re-install needed)
  • Debug logging toggle directly in the HA UI
  • German and English translations

Supported Devices

Device Status
EcoFlow PowerOcean Plus ✅ Confirmed
EcoFlow PowerOcean ✅ Confirmed
EcoFlow PowerOcean Connect ❓ Untested – feedback welcome

Prequesites

The ModBus must be enabled by your EcoFlow Partner / Installer, it is disabled by default!


Installation

Via HACS (recommended)

  1. Open HACS in Home Assistant
  2. Go to IntegrationsCustom repositories
  3. Add https://github.com/MaxGrmm/EF-PowerOcean-TcpModbus as category Integration
  4. Click Install
  5. Restart Home Assistant

Manual

  1. Download the latest release
  2. Copy the custom_components/ef_powerocean_tcpmodbus folder to your HA config/custom_components/ directory
  3. Restart Home Assistant

Configuration

  1. Go to Settings → Devices & Services → Add Integration
  2. Search for EF-PowerOcean-TcpModbus
  3. Fill in the setup form:
Field Default Description
IP Address Local IP of your PowerOcean Plus
Port 502 Modbus TCP port
Battery Capacity (kWh) 5.0 Usable capacity of your battery module
Number of PV Strings 2 Active strings connected to the inverter (1–3)
Poll Interval (seconds) 10 How often values are fetched

To change settings after setup: Settings → Devices & Services → EF-PowerOcean-TcpModbus → Configure


Available Sensors

Power (real-time)

Sensor Unit Description
House Power W Current house consumption
Grid Power W Grid exchange (negative = export)
Solar Power W Total PV generation (sum of active strings)
Battery Power W Battery charge/discharge power
Inverter AC Power W Total AC output of inverter

Battery

Sensor Unit Description
Battery SOC % State of charge
Battery Remaining Energy kWh Calculated from SOC × configured capacity
Battery Voltage V DC bus voltage
Battery Current A Positive = charging, negative = discharging
Battery Temperature °C Battery temperature
Battery Nominal Capacity kWh User-configured capacity

Solar

Sensor Unit Description
PV String 1/2/3 Power W Per-string power (current × PV voltage)
PV String 1/2/3 Current A MPPT string current
PV Voltage Global V Common PV bus voltage

AC Grid

Sensor Unit Description
Grid Voltage L1/L2/L3 V Per-phase voltage
Grid Current L1/L2/L3 A Per-phase current
Grid Frequency Hz Grid frequency
Grid Apparent Power VA Total apparent power
Inverter Temperature °C Inverter temperature

Limits (Diagnostic)

Sensor Unit Description
Inverter Nominal Power Limit W Maximum inverter output
Inverter Current Max Power W Current active power limit
Max Battery Discharge Power W Calculated: 3300 W × number of modules
Max Charge Power W Calculated: 2500 W × number of modules
Min SOC Limit % Configured minimum state of charge

Energy – Today

Sensor Unit Description
House Consumption Today kWh Calculated from energy balance
Solar Yield Today kWh Total solar energy generated today
Grid Import Today kWh Energy imported from grid today
Grid Export Today kWh Energy exported to grid today
Battery Charged Today kWh Energy charged today
Battery Discharged Today kWh Energy discharged today

Energy – Lifetime

Sensor Unit Description
House Consumption Total kWh Calculated from energy balance
Solar Yield Total kWh Lifetime solar generation
Grid Import Total kWh Lifetime grid import
Grid Export Total kWh Lifetime grid export
Battery Charged Total kWh Lifetime energy charged
Battery Discharged Total kWh Lifetime energy discharged
Battery Net Energy kWh Charged minus discharged

Debug Logging

To enable debug logging without editing configuration.yaml:

  • Settings → Devices & Services → EF-PowerOcean-TcpModbus → Enable debug logging

Screenshots

Screenshot 2026-04-02 132824 Screenshot 2026-04-02 132833

Technical Details

  • Protocol: Modbus TCP (port 502)
  • Register type: Holding Registers (Function Code 3)
  • Float encoding: 32-bit IEEE 754, little-endian word order (word-swapped)
  • Read strategy: Block reads (5 requests per poll cycle)
  • Tested firmware: 3.0.15.10
  • Tested pymodbus version: 3.6.9 and 3.11.x

Full register map: EcoFlow_PowerOcean_Modbus.md


Contributing

Pull requests are welcome! Especially:

  • Testing on other EcoFlow devices (PowerOcean DC, Connect)
  • Identifying further Modbus registers
  • Home Assistant Energy Dashboard configuration examples

Please open an issue before submitting large changes.


Credits

Special thanks to Kater Carlo for his significant contributions to register mapping, sensor definitions and testing – this release would not have happened without him. 🐱


Disclaimer

This integration was developed through community reverse engineering. EcoFlow does not officially support or document this Modbus interface. Use at your own risk. Not affiliated with EcoFlow Technology Co., Ltd.


License

MIT License – free to use, modify and distribute with attribution.

About

Local Home Assistant Modbus TCP integration for EcoFlow PowerOcean – no cloud required