Skip to content

Added scan for MPP in both directions, invert starting direction each time, dynamic dAngleMax#9

Open
ilario wants to merge 2 commits intoAFMD:masterfrom
ilario:master-fwd_and_rev_scan
Open

Added scan for MPP in both directions, invert starting direction each time, dynamic dAngleMax#9
ilario wants to merge 2 commits intoAFMD:masterfrom
ilario:master-fwd_and_rev_scan

Conversation

@ilario
Copy link
Copy Markdown
Contributor

@ilario ilario commented Jul 24, 2017

Here I join three rather big changes, if you prefer I can submit separated PR, depending on which of these changes you agree on.

  1. the scan now looks for a MPP in a forward scan and for another in a reverse scan, uses the average of these two as the real MPP
  2. the "walking to" steps are not used for MPP search, just the scans
  3. the scan starts each time in a different direction, 'cause also this has an influence in the resulting MPP position
  4. a dAngleMax of 25 degrees means that each scan is rather big, triggering more hysteretic effects and taking more time, here I implement a dynamic dAngleMax which decreases (the minimum is limited by dAngleMinLimit) as the Vmpp gets stable

@ilario
Copy link
Copy Markdown
Contributor Author

ilario commented Nov 20, 2017

This works very well with silicon reference cell (obviously)

(voltage is black, current is red, efficiency is green)

Si cell

in perovskite cells just improves the measurement quality reducing the hysteresis triggered by a smaller scan

ig92-spiro-1456-1-led437penta

but further improvement is needed, see also #12

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.